SIEMENS
6/133
Siemens NC 62 · 2016
Main spindle motors
SIMOTICS M synchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> SH 180 – Forced ventilation/Water cooling
6
Motor type
(repeated)
Effi-
ciency
Moment
of inertia
without
holding
brake
Weight,
approx.
without
holding
brake
Rated
current
S1 duty
Stall
current
S1 duty
接线盒
SINAMICS S120 Motor Module
Rated
output current
3)
S1 duty
For other versions
and components,
see SINAMICS S120
drive system
η
J
m
I
rated
I
0
I
rated
%
kgm
2
(lb
f
-in-s
2
)
kg (lb)
A
A
Type
A
Article No.
1PH8184-..C...
92.6
0.46 (4.07)
330 (728)
80.0
84
1XB7322-P05
85
6SL312
■
-
1TE28
-
5AA3
1PH8184-..D...
94.2
0.46 (4.07)
330 (728)
106
115
1XB7322-P05
132
6SL312
■
-
1TE31
-
3AA3
1PH8184-..F...
95.4
0.46 (4.07)
330 (728)
150
157
1XB7322-P05
200
6SL312
■
-
1TE32
-
0AA4
1PH8186-..C...
93.1
0.60 (5.31)
400 (882)
108
115
1XB7322-P05
132
6SL312
■
-
1TE31
-
3AA3
1PH8186-..D...
94.8
0.60 (5.31)
400 (882)
148
157
1XB7322-P05
200
6SL312
■
-
1TE32
-
0AA4
1PH8186-..F...
95.5
0.60 (5.31)
405 (893)
215
229
1XB7422-P06
260
6SL332
0
-
1TE32
-
6 aa3
1PH8184-..C2..
92.6
0.457 (4.04)
330 (728)
102
103
1XB7322-P05
132
6SL312
■
-
1TE31
-
3AA3
1PH8184-..D2..
94.2
0.457 (4.04)
330 (728)
140
143
1XB7322-P05
200
6SL312
■
-
1TE32
-
0AA4
1PH8184-..F2..
95.4
0.457 (4.04)
330 (728)
186
196
1XB7322-P05
200
6SL312
■
-
1TE32
-
0AA4
1PH8184-..L2..
95.6
0.457 (4.04)
330 (728)
250
278
1XB7700-P02
260
4)
6SL332
0
-
1TE32
-
6 aa0
1PH8186-..C2..
93.1
0.599 (5.30)
400 (882)
142
143
1XB7322-P05
200
6SL312
■
-
1TE32
-
0AA4
1PH8186-..D2..
94.8
0.599 (5.30)
400 (882)
190
196
1XB7322-P05
200
6SL312
■
-
1TE32
-
0AA4
1PH8186-..F2..
95.5
0.599 (5.30)
400 (882)
275
285
1XB7700-P02
310
6SL332
0
-
1TE33
-
1AA0
1PH8186-..L2..
95.5
0.599 (5.30)
400 (882)
340
405
1XB7700-P02
380
4)
6SL332
0
-
1TE33
-
8AA0
Format:
Booksize
Chassis
1
3
Cooling:
Internal air cooling
External air cooling
0
1
Motor Module:
Single Motor Module
1
3)
The rated pulse frequencies must be taken into account. The rated motor data is valid for 4 kHz (booksize format) or 2 kHz (chassis format).
4)
The rated output current of the Motor Module is lower than the motor rated current or the motor stall current at 4 kHz or 2 kHz.
© Siemens AG 2016