SIEMENS
6/125
Siemens NC 62 · 2016
主轴电机
SIMOTICS M asynchronous motors for SINAMICS S120
SIMOTICS M-1PH8
> Terminal box assignment, max. connectable cable cross-sections
6
■
选项
(继续)
接线盒
类型
(参见选择
and ordering data
任务)
电缆入口
Outer
cable
diameter,
最大限度。
1)
主码头数量
横截面
每个终端,
最大限度。
评分为
当前的,
最大限度。
2)
Power
External signals
mm (in)
mm².
A
gk803
1
×
M25
×
1.5
1
×
M16
×
1.5
3)
20.(0.79)
阶段:
3
×
M5
1
×
10
52.
接地:2
×
M5
gk813
1
×
M32.
×
1.5
1
×
M16
×
1.5
3)
24..2 (0.95)
阶段:
3
×
M5
1
×
16
70
接地:2
×
M5
gk823
1
×
M32.
×
1.5
1
×
M16
×
1.5
3)
24..2 (0.95)
阶段:
3
×
M5
1
×
16
70
接地:2
×
M5
gk826
1
×
M32.
×
1.5
1
×
M16
×
1.5
3)
24..2 (0.95)
阶段:
6
×
M5
1
×
10
52.
接地:2
×
M5
gk833
1
×
M40
×
1.5
1
×
M16
×
1.5
3)
32(1.26)
阶段:
3
×
M6
1
×
35
110
接地:2
×
M6
gk843
1
×
M50
×
1.5
1
×
M16
×
1.5
3)
38.(1.50)
阶段:
3
×
M6
1
×
50.
133.
接地:2
×
M6
gk846
1
×
M50
×
1.5
1
×
M16
×
1.5
3)
38.(1.50)
阶段:
6
×
M6
1
×
25.
88.
接地:2
×
M6
gk863
1
×
M50
×
1.5
1
×
M16
×
1.5
3)
38.(1.50)
阶段:
3
×
M6
1
×
50.
133.
接地:2
×
M6
gk873
1
×
M63.
×
1.5
1
×
M16
×
1.5
3)
42..6 (1.68)
阶段:
3
×
M6
1
×
50.
133.
接地:2
×
M6
1XB7322-P05
2
×
M50
×
1.5
1
×
M16× 1.5
4)
38.(1.50)
阶段:
3
×
M12.
2
×
50.
21.0
接地:2
×
M6
1XB7422-P06
2
×
M63.
×
1.5
1
×
M16× 1.5
4)
53(2.09)
阶段:
3
×
M12.
2
×
70
270.
接地:4
×
M8
1XB7700-P02
3
×
M75.
×
1.5
1
×
M16× 1.5
4)
68(2.68)
阶段:
3
×
2
×
M12.
3
×
150.
700
接地:3
×
fixing eyelet
1XB7712-P03
4
×
M75.
×
1.5
1
×
M16× 1.5
4)
68(2.68)
阶段:
3
×
4
×
M16
4
×
185.
1150
接地:4
×
M16
用于接线盒式
1XB7712-P01
or
1XB7712-P03
,可以订购其他电缆条目(电源)
通过P选项取决于标准:
P00.
P01.
P02.
P03.
P04.
Undrilled cable entry plate
电缆入口板3×M63×1.5(不是1xb7712-p01)
电缆入口plate 3 × M75 × 1.5
电缆入口plate 4 × M75 × 1.5 (not with 1XB7712-P03)
电缆入口plate 4 × M63 × 1.5
用于接线盒式
1XB7700-P02
,可以订购其他电缆条目(电源)
通过P选项取决于标准:
P00.
P01.
Undrilled cable entry plate
电缆入口plate 3 × M63 × 1.5
用于接线盒式s
1XB7322-P05
and
1XB7422-P06
, another cable entry (power) can be ordered
via the P option depending on the standard:
P00.
Undrilled cable entry plate
With option
K09.
or
K10
, terminal box
gk873
mounted on the side is used instead of terminal box
gk863
.
With option
K09.
or
K10
, terminal box
gk843
mounted on the side is used instead of terminal box
gk833
.
With option
K09.
or
K10
, terminal box
gk823
mounted on the side is used instead of terminal box
gk813
.
1)
Dependent on the design of the metric cable gland.
2)
Current-carrying capacity based on EN 60204-1/IEC 60364-5-52 with installation type E.
3)
螺纹M16×1.5以90°布置为信号连接;仅使用选项A12,A25以及第9个数据位置时的线程(没有编码器)。
4)
Thread M16 × 1.5 arranged opposite the signal connection (lateral to the cable entry plate); thread only with option A12 and when 9th data position
is A (without encoder).
©Siemens AG 2016