SINUMERIK CNC
Functions
Drive functions
2
Drive functions
(continued)
Drive Control Chart DCC
不可能的integra -
ted drives. Included in
basic scope on external
SINAMICS S120 drives.
–
–
Drive Based Open Architecture
Drive-related functions
can be developed in
partnership with Siemens
on request.
Basic positioner
不可能的integra -
ted drives. Included in
basic scope on external
SINAMICS S120 drives.
–
–
2 command data sets
–
–
Parallel connection of SINAMICS S120 Motor Modules
–
–
Maximum configuration
valid for standard PROFIBUS DP cycle with:
• Current/speed controller cycle 125 μs:
- Axes/spindles
31
31
-
Axes/spindles per NCU or NX
6
6
-
Motor measuring systems and direct measuring
systems per NCU or NX
12
12
• Current/speed controller cycle 62.5 μs:
- Axes/spindles
11
11
-
Axes/spindles per NCU or NX
3
3
• Current/speed controller cycle 31.25 μs:
- Axes/spindles
1
1
• SINAMICS S120 chassis format
Motor Modules per NCU or NX
6
6
Current/speed controller cycle:
• SINAMICS S120 booksize format, minimum
31.25 μs
31.25 μs
• SINAMICS S120 chassis format, minimum
125 μs
125 μs
• Maximum
250 μs
250 μs
PROFIBUS DP cycle (corresponds to IPO cycle),
minimum
0.5 ms
0.5 ms
Drive data sets, maximum number
32
32
Motor data sets, maximum number
16
16
Encoder data sets, maximum number
8
8
Description
Instructions
(footnotes are applicable
line by line)
Article No.
Order
code
SINUMERIK
Basic version
O Option
– Not available
Type
840DE sl
840D sl
© Siemens AG 2016