SIEMENS
5/68
Siemens NC 62 · 2016
5
SINAMICS S120 drive system
Booksize format – DC link components
Braking Module
■
Overview
1
Braking Module
A Braking Module and the matching external braking resistor
are required to bring drives to a controlled standstill in the event
of a power failure (e.g., emergency retraction or
EMERGENCY OFF category 1) or limit the DC link voltage for
brief periods of generator operation, e.g., when the regenerative
feedback capability of the Line Module is deactivated. The
Braking Module includes the power electronics and the associ-
ated control circuit. During operation, the DC link power is con-
verted into heat loss in an external braking resistor. Braking
Modules function autonomously.
Braking modules in booksize format can also be used for rapid
discharge of the DC link.
■
Design
The Braking Module in booksize format features the following
connections and interfaces as standard:
•
2通过集成直流链路连接DC link busbars
•
2 electronics power supply connections via integrated
24 V DC busbars
•
Terminals for connecting the braking resistor
•
2 digital inputs (disable Braking Module/acknowledge faults
and rapid discharge of DC link)
•
2 digital outputs (Braking Module disabled and
prewarning
I
×
t
monitoring)
•
2 PE connections
The status of the Braking Module is indicated via two 2-color
LEDs.
■
Technical specifications
■
Selection and ordering data
1)
Several Braking Modules can be operated in parallel, typically
up to 4 Modules.
Article No.
6SL3100-1AE31-0AB1
Product designation
Braking Module
in booksize format
with internal air cooling
DC link voltage 510 … 720 V DC
Rated power
P
DB
1.5 kW
1)
Peak power
P
max
100 kW
1)
Activation threshold
770 V
Cable length, max.
to braking resistor
10 m (32.8 ft)
DC link capacitance
110
µ
F
Power requirement at 24 V DC,
max.
0.5 A
Digital inputs
符合IEC 61131-2
Type 1
• Voltage
-3 … +30 V
• Low level
(an open digital input is
interpreted as "low")
-3 … +5 V
• High level
15 … 30 V
• Current consumption at 24 V DC,
typ.
10 mA
• Conductor cross-section, max.
1.5 mm
2
Digital outputs
Continuously short-circuit-proof
• Voltage DC
24 V
• Load current per digital output,
max.
100 mA
• Conductor cross-section, max.
1.5 mm
2
Current carrying capacity
• 24 V DC busbars
20 A
• DC link busbars
100 A
PE connection
M5 screw
Width
50 mm (1.97 in)
Height
380 mm (14.96 in)
Depth, with spacer
270 mm (10.63 in)
Net weight
4.1 kg (9 lb)
Certificate of suitability
cURus
Description
Article No.
Braking Module
in booksize format
Internal air cooling,
incl. spacers
6SL3100-1AE31-0AB1
Accessories for re-ordering
Warning labels
in 30 languages
This label set can be glued over
the standard English or German
labels to provide warnings in other
languages.
One set of labels is supplied with
the devices.
One sign in each of the following
languages is provided in each set:
BG, CN, CZ, DE, DK, EE, ES, FI,
FR, GB, GR, HU, IE, IS, IT, JP, KR,
LT, LV, MT, NL, NO, PL, PT, RO, RU,
SE, SI, SK, TR
6SL3166-3AB00-0AA0