SIEMENS
7/13
Siemens NC 82 · 2017
MOTION-CONNECT connection systems
Signal cables
7
■
Overview
MOTION-CONNECT DRIVE-CLiQ signal cable with IP20/IP67 connector
Signal cables are pre-assembled and are sold by the meter for
the connection of a variety of components.
The following different types of cable are available:
•
DRIVE-CLiQ signal cables
•
MOTION-CONNECT DRIVE-CLiQ signal cables
•
MOTION-CONNECT pre-assembled signal cables
■
Application
DRIVE-CLiQ signal cables
DRIVE-CLiQ signal cables are used to connect components with
DRIVE-CLiQ connections which have a separate or external
24 V DC power supply.
MOTION-CONNECT DRIVE-CLiQ signal cables
MOTION-CONNECT DRIVE-CLiQ signal cables with 24 V DC
cores are used whenever components with DRIVE-CLiQ con-
nections must meet high requirements such as mechanical
stress and oil resistance, e.g. where a connection is made out-
side the cabinet between Power Modules/Motor Modules and
SIMOTICS S-1FK7/ SIMOTICS M-1PH8 motors with DRIVE-CLiQ
interface.
MOTION-CONNECT pre-assembled signal cables
MOTION-CONNECT pre-assembled signal cables are used
whenever motor encoders on motors without DRIVE-CLiQ inter-
face are connected to Sensor Modules.
Type of delivery for pre-assembled signal cables
Pre-assembled signal cables are available in units of 10 cm.
The cables are supplied on reels up to 30 kg or 100 m. Above
30 kg or 100 m, cable drums are used instead of reels.
■
Technical specifications
Article No.
6FX2...-1DC..-
....
6 fx5…-.DC . . -
....
6FX8...-.DC..-
....
Product name
MOTION-CONNECT 500
MOTION-CONNECT 800PLUS
Product designation
DRIVE-CLiQ signal cable
DRIVE-CLiQ signal cable
DRIVE-CLiQ signal cable
Certificate of suitability
•cURus或UR/CSA
1)
UL STYLE 2502/CSA-N.210.2-M90
UL STYLE 2502/CSA-N.210.2-M90
UL STYLE 2502/CSA-N.210.2-M90
• RoHS conformity
Yes
Yes
Yes
Rated voltage
30 V
30 V
30 V
Test voltage, rms
500 V
500 V
500 V
Operating temperature
on the surface
• Fixed installation
-20 … +80 °C
-20 … +80 °C
-50 … +80 °C
• Flexible installation
–
0 … 60 °C
-20 … +60 °C
Tensile stress, max.
• Fixed installation
45 N/mm
2
80 N/mm
2
50 N/mm
2
• Flexible installation
–
30 N/mm
2
20 N/mm
2
Smallest bending radius
• Fixed installation
50 mm
35 mm
35 mm
• Flexible installation
–
125 mm
75 mm
Torsional stress
–
Absolute 30°/m
Absolute 30°/m
Bending
–
100000
10 million
Traversing velocity
–
30 m/min
300 m/min
Acceleration
–
2 m/s
2
Up to 50 m/s
2
Insulation material,
incl. jacket
FCKW/silicone-free
FCKW/silicone-free
FCKW/halogen/silicone-free
IEC 60754-1/DIN VDE 0472-815
Oil resistance
EN 60811-2-1
EN 60811-2-1 (mineral oil only)
EN 60811-2-1
Outer jacket
PVC
PVC
PUR, HD22.10 S2
(VDE 0282, Part 10)
Gray RAL 7032
DESINA color green RAL 6018
DESINA color green RAL 6018
Flame-retardant
EN 60332-1-1 to 1-3
EN 60332-1-1 to 1-3
EN 60332-1-1 to 1-3
1)
The UR-CSA File No. is printed on the cable jacket.
© Siemens AG 2016