SIEMENS
4/55
Siemens NC 82 · 2017
SINAMICS S120 drive system
Supplementary system components
TM54F Terminal Module
4
■
Technical specifications
Article No.
6SL3055-0AA00-3BA0
Product brand name
SINAMICS
Product type designation
S120
Product designation
Terminal Module TM54F
Power requirement at 24 V DC
(X524) without DRIVE-CLiQ supply
0.2 A
• Conductor cross-section,
maximum
2.5 mm
2
• Fuse protection, maximum
20 A
Power requirement, external at
24 V DC, maximum
For supplying the digital outputs
and 24 V sensor supply (X514 at
24 V DC)
4 A
• Conductor cross-section,
maximum
2.5 mm
2
• Fuse protection, maximum
20 A
I / O
• Number of fail-safe
digital inputs
10
• Number of fail-safe
digital outputs
4
• 24 V sensor supply
3.
of which 2 can be temporarily shut
down using an internal test routine
for dynamizing fail-safe digital
inputs,
current carrying capacity
0.5 A each
• Connection method
Plug-in screw-type terminals
• Conductor cross-section,
maximum
1.5 mm
2
Digital inputs
按照IEC61131-2
Type 1, with galvanic isolation
• Voltage
-3 … +30 V
• Low level
an open digital input is
interpreted as "low"
-3 … +5 V
• High level
15 … 30 V
• Current consumption, typical
-
At 24 V DC
> 2 mA
•
Delay time of digital inputs,
approx.
1)
- L
→
H typical
30.μs
- H
→
L typical
60 μs
• Safe state
Low level
For inputs that can be inverted:
没有反转
Digital outputs
Sustained-short-circuit-proof
• Voltage DC
24 V
• Load current per fail-safe digital
output, maximum
2)
0.5 A
• Delay times at resistive load
1)
- L
→
H typical
30.0 μs
- H
→
L typical
350 μs
• Safe state
Output switched off
Scanning cycle
t
SI
For fail-safe digital inputs or
fail-safe digital outputs
4 ... 25 ms
adjustable
Power loss at 24 V DC, maximum
4.5 W
PE connection
M4 screw
Width
50 mm
Height
151 mm
Depth
110 mm
Net weight
0.48 kg
Certificate of suitability
cULus
Safety Integrated
According to IEC 61508 SIL 2
and EN ISO 13849-1 PL d
and category 3
Article No.
6SL3055-0AA00-3BA0
Product brand name
SINAMICS
Product type designation
S120
Product designation
Terminal Module TM54F
1)
The specified delay times refer to the hardware. The actual reaction time
depends on the time slot in which the digital input/output is processed.
2)
The total current of all fail-safe digital outputs must not exceed 5.33 A.
© Siemens AG 2016