SIEMENS
2/2
Siemens NC 81.1 · 2017
Overview of functions
SINUMERIK 808D family
Control structure and configuration/Drives/Connectable measuring systems
2
Basic version
O
Option
–
Not available
Article No.
SINUMERIK 808D
PPU 141.1
SINUMERIK 808D ADVANCED
PPU 160.3/PPU 161.3
Note
Turning
Milling
Turning
Milling
Control structure and configuration
Panel-based control system comprising:
• Compact operator panel
• CNC/PLC Control Unit
• Onboard digital PLC inputs/outputs
• CF card with system software Export version
Turning
Milling
Turning
Milling
SINUMERIK operator panel CNC:
• Operator panel layout
horizontal/vertical
/–
/–
/
/
• Color display
7.5"
7.5"
8.4"
8.4"
• Display resolution
640 × 480
640 × 480
800 × 600
800 × 600
• Integrated CNC keyboard with hard keys
• Specific CNC keyboard layout for
Turning
Milling
Turning
Milling
• Operator panel with Simplified Chinese layout
• Operator panel with English layout
利用西门子基本操作
Quantity of pulse/direction interfaces for
feed axis converter
3
3
–
–
Quantity of bus interfaces for axis converter
–
–
1
1
Quantity of analog ±10 V interfaces for
主轴变频器
1
1
1
1
Channels/mode groups MG:
• Maximum configuration
1
1
1
1
CNC user memory (buffered) for
CNC part programs
The 1.25 MB memory is
for storing and editing
the user program. There
is another 500 MB
memory for NC program
storage.
1.25 MB
1.25 MB
1.25 MB
1.25 MB
Axes/spindles:
• Basic quantity of axes/spindles
3
4
3
4
• Maximum configuration axes/spindles
4
4
5
5
• Axis/spindle, each additional
6FC5800-0AK70-0YB0
O
–
O
O
Drives
Feed drives:
• SINAMICS V60 via pulse/direction interface
O
O
–
–
• SINAMICS V70 via bus interface
–
–
O
O
• 3rd-party feed axis converter via pulse/
direction interface
O
O
–
–
Spindles:
• Analog Drive Interface
O
O
O
O
SINAMICS V70 spindle via bus interface
–
–
O
O
Connectable measuring systems
Number of measuring systems per axis, max.
1
1
1
1
Incremental encoder installed in
SIMOTICS S-1FL5 feed motors
–
–
Incremental encoder installed in
SIMOTICS S-1FL6 feed motors
–
–
Absolute encoder installed in
SIMOTICS S-1FL6 feed motors
–
–
Incremental encoder installed in
SIMOTICS M-1PH1 main motors
–
–
RS422 (TTL) direct incremental spindle encoder
6FX2001-2EB02
O
O
O
O
© Siemens AG 2016