SIEMENS
12/24
Siemens D 21.4 · 2017
MOTION-CONNECT connection systems
Signal cables for SINAMICS S120
12
■
Technical specifications
Degree of protection of the pre-assembled signal cables and their extensions when closed and inserted: IP67.
DRIVE-CLiQ signal cables
DRIVE-CLiQ
DRIVE-CLiQ
MOTION-CONNECT 500
DRIVE-CLiQ
MOTION-CONNECT 800PLUS
6FX2...-1DC..-
....
6FX5...-.DC..-
....
6FX8...-.DC..-
....
Certificate of suitability
•cURus或你/ CSA
UL STYLE 2502/CSA-N.210.2-M90
UL STYLE 2502/CSA-N.210.2-M90
UL STYLE 2502/CSA-N.210.2-M90
• UR-CSA File No.
1)
Yes
Yes
Yes
• RoHS conformity
Yes
Yes
Yes
Rated voltage
according to EN 50395
30 V
30 V
30 V
Test voltage, rms
500 V
500 V
500 V
Operating temperature
on the surface
• Fixed installation
-20 … +80 °C (-4 ... +176 °F)
-20 … +80 °C (-4 ... +176 °F)
-20 … +80 °C (-4 ... +176 °F)
• Flexible installation
- - - - - -
0 … 60 °C (32 ... 140 °F)
-20 … +60 °C (-4 ... +140 °F)
Tensile stress, max.
• Fixed installation
45 N/mm
2
(6526 lb/in
2
)
80 N/mm
2
(11603 lb/in
2
)
50 N/mm
2
(7252 lb/in
2
)
• Flexible installation
- - - - - -
30 N/mm
2
(4351 lb/in
2
)
20 N/mm
2
(2901 lb/in
2
)
Smallest bending radius
• Fixed installation
50 mm (1.97 in)
35 mm (1.38 in)
35 mm (1.38 in)
• Flexible installation
- - - - - -
125 mm (4.92 in)
75 mm (2.95 in)
Torsional stress
- - - - - -
Absolute 30°/m
Absolute 30°/m
Bending
- - - - - -
100000
10 million
Traversing velocity
- - - - - -
30 m/min (98.4 ft/min)
300 m/min (984 ft/min)
Acceleration
- - - - - -
2 m/s
2
(6.56 ft/s
2
)
Up to 50 m/s
2
(164 ft/s
2
),
see characteristics on page 12/5
Insulation material,
incl. jacket
CFC/silicone-free
CFC/silicone-free
CFC/halogen-free/silicon-free
IEC 60754-1/DIN VDE 0472-815
Oil resistance
EN 60811-2-1
EN 60811-2-1 (mineral oil only)
EN 60811-2-1
Outer jacket
PVC
PVC
PUR, HD22.10 S2
(VDE 0282, Part 10)
Gray RAL 7032
DESINA绿色文化、6018年
DESINA绿色文化、6018年
Flame-retardant
EN 60332-1-1 to 1-3
EN 60332-1-1 to 1-3
EN 60332-1-1 to 1-3
1)
The File No. is printed on the cable jacket.
© Siemens AG 2017