SIEMENS
7/278
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Blocksize format
Safe Brake Relay for blocksize format
7
■
Overview
Safe Brake Relay
With the Safe Brake Relay, the brake is controlled in accordance
with IEC 61508 SIL 2 and EN ISO 13849-1 PL d and Category 3.
■
Design
The Safe Brake Relay can be installed below the Power Module
on the shield connection plate.
The Safe Brake Relay has the following connections and
interfaces:
•
1 two-channel transistor output stage to control the motor
brake solenoid
•
1 connection for the cable harness (CTRL) to the Power
模块blocksize格式
•
1 connection for the 24 V DC power supply
The connection between the 24 V DC supply and the
Safe Brake Relay must be kept as short as possible.
The scope of supply of a Safe Brake Relay includes the
following
:
•
2 cable harnesses for connecting to the CTRL socket of the
Power Module
- Length 0.32 m (1.05 ft) for frame sizes FSA to FSC
- Length 0.55 m (1.80 ft) for frame sizes FSD to FSF
■
Selection and ordering data
■
Technical specifications
■
Integration
Connection example of a Safe Brake Relay
The 24 V DC solenoid of the motor brake is directly connected
to the Safe Brake Relay. External overvoltage limiters are not
required.
Description
Article No.
Safe Brake Relay
Including cable harness for connection
to Power Module
6SL3252-0BB01-0AA0
Safe Brake Relay
6SL3252-0BB01-0AA0
Power supply
20..4 ... 28.8 V DC
Recommended rated supply
voltage 26 V DC
(to compensate for voltage
drop in feeder cable to
24 V DC motor brake
solenoid)
Current requirement, max.
• Motor brake
2 A
• At 24 V DC
0.05 A + the current
requirement of motor brake
Conductor cross-section, max.
2.5 mm
2
Dimensions
• Width
69 mm (2.72 in)
• Height
63 mm (2.48 in)
• Depth
33 mm (1.30 in)
Weight, approx.
0.17 kg (0.37 lb)
U2
V2
W2
PE
M
3 ~
Safe Brake Relay
CTRL
M
+
M
+
M
+
BR-
BR+
G_D211_EN_00071a
ext.
24 V
PM-IF interface
Cable harness
Power Module
© Siemens AG 2017