SIEMENS
7/247
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Blocksize format
Air-cooled Power Modules in blocksize format
7
■
Technical specifications
(continued)
Line voltage 200 ... 240 V 3 AC
PM240-2 Power Modules standard variant
Without integrated line filter
6SL3210-
1PC28-0UL0
6SL3210-
1PC31-1UL0
6SL3210-
1 pc31-3ul0
6SL3210-
1PC31-6UL0
6SL3210-
1PC31-8UL0
With integrated line filter class A
- - - - - -
- - - - - -
- - - - - -
- - - - - -
- - - - - -
Output current
at 50 Hz 230 V 3 AC
• Rated current
I
rated
1)
A
80
104
130
154
178
• For S6 duty (40 %)
I
S6
A
96
124
156
184
213
• Base-load current
I
H
2)
A
68
80
104
130
154
• Maximum current
I
max
A
136
160
208
260
308
Type rating
• Based on
I
rated
kW (hp)
22 (30)
30 (40)
37 (50)
45 (60)
55 (75)
• Based on
I
H
kW (hp)
18.5 (25)
22 (30)
30 (40)
37 (50)
45 (60)
Rated pulse frequency
kHz
4
4
4
4
4
Efficiency
η
%
>97
>97
>97
>97
>97
Power loss
3)
at rated current
kW
0.85
1.2
1.44
1.79
2.18
Cooling air requirement
m
3
/s (ft
3
/s)
0.083 (2.9)
0.083 (2.9)
0.153 (5.4)
0.153 (5.4)
0.153 (5.4)
Sound pressure level
L
pA
(1 m)
dB
44 ... 62
4)
44 ... 62
4)
56 ... 68
4)
56 ... 68
4)
56 ... 68
4)
24 V DC power supply
for Control Unit
A
1
1
1
1
1
Input current
5)
• Rated current
A
83
107
134
158
183
• Based on
I
H
A
71
83
110
138
164
Line supply connection
U1/L1, V1/L2, W1/L3
Screw terminals
Screw terminals
M10 screw stud
M10 screw stud
M10 screw stud
• Conductor cross-section
mm
2
25 ... 70
25 ... 70
35 ... 2 × 120
35 ... 2 × 120
35 ... 2 × 120
Motor connection
U2, V2, W2
Screw terminals
Screw terminals
M10 screw stud
M10 screw stud
M10 screw stud
• Conductor cross-section
mm
2
25 ... 70
25 ... 70
35 ... 2 × 120
35 ... 2 × 120
35 ... 2 × 120
PE connection
Screw terminals
Screw terminals
M10 screw stud
M10 screw stud
M10 screw stud
Motor cable length, max.
• Shielded
m (ft)
200 (656)
200 (656)
300 (984)
300 (984)
300 (984)
• Unshielded
m (ft)
300 (984)
300 (984)
450 (1476)
450 (1476)
450 (1476)
Degree of protection
IP20
IP20
IP20
IP20
IP20
Dimensions
• Width
mm (in)
275 (10.83)
275 (10.83)
305 (12.01)
305 (12.01)
305 (12.01)
• Height
mm (in)
551 (21.69)
551 (21.69)
708 (27.87)
708 (27.87)
708 (27.87)
• Depth without operator panel
mm (in)
237 (9.33)
237 (9.33)
357 (14.06)
357 (14.06)
357 (14.06)
Frame size
FSE
FSE
FSF
FSF
FSF
Weight, approx.
• Without integrated line filter
kg (lb)
26 (57.3)
26 (57.3)
57 (126)
57 (126)
57 (126)
• With integrated line filter
kg (lb)
- - - - - -
- - - - - -
- - - - - -
- - - - - -
- - - - - -
1)
The rated output current
I
rated
is based on the duty cycle for low overload
(LO).
2)
The base-load current
I
H
is based on the duty cycle for high overload
(HO).
3)
Typical values. You can find additional information on the Internet at
4)
Values dependent on ambient temperature and utilization.
5)
The input current depends on the motor load and line impedance. The
input currents apply for a load with the type rating (based on
I
rated
) for a
line impedance corresponding to
u
k
= 1 %. The current values are
specified on the rating plate of the Power Module.
© Siemens AG 2017