SIEMENS
7/176
Siemens D 21.4 · 2017
SINAMICS S120 drive system
Chassis format
Liquid-cooled Active Line Modules in chassis format
7
■
Integration
Active Line Modules are always operated together with the
associated Active Interface Modules. Active Interface Modules
contain a Clean Power Filter with basic RI suppression, the pre-
charging circuit for the Active Line Module, line supply voltage
sensing circuit and monitoring sensors.
的李quid-cooled Active Line Modules communicate with the
higher-level control module via DRIVE-CLiQ. The control module
in this case can be a CU320-2 or a SIMOTION D Control Unit. An
external 24 V DC power supply is required to operate the Active
Line Modules.
一个活跃的线模块连接的例子
■
Technical specifications
General technical specifications
ext.
24 V DC
DC link
Cooling circuit
G_D213_EN_00040b
Internal
power supply
Activation of
bypass contactor
Activation of
pre-charging
contactor
to Active
Interface Module
from Active
Interface Module
DRIVE-CLiQ socket
DRIVE-CLiQ socket
DRIVE-CLiQ socket
P24 V
EP +24 V
EP +24 V
-Temp
Active Line
Module
Chassis Format
X402
X401
X400
-X41
DCP
DCN
3
4
1
2
EP M1
EP M1
M
-X9
-X1
2
1
4
6
5
8
7
READY
LEDs
DC LINK
POWER OK
3
=
=
=
~
U1
V1
W1
PE
P24L
P24L
M
M
-X42
1
2
3
4
IPD Card
1
2
0
+Temp
-Temp
Electrical specifications
Line power factor
• Basic fundamental (cos
ϕ
1
)
1 (factory setting), can be altered by inputting a reactive current setpoint
• Total (
λ
)
1 (factory setting)
Efficiency
>98.5 % (Active Line Modules)
>99 % (Active Interface Module)
DC link voltage, approx.
The DC link voltage is regulated and can be adjusted as a voltage decoupled from the line voltage.
Factory setting of the DC link voltage: 1.5 × line voltage
© Siemens AG 2017