SIEMENS
SINAMICS GM150
Medium-Voltage Converter
SINAMICS GM150 in IGBT version
2/21
Siemens D 12 · 2012
2
■
Technical specifications
Example 1 (air-cooled converter)
Derating data SINAMICS GM150 in IGBT version
For the current, the following applies:
I
≤
I
N
× 0.84 × 1.0 =
I
N
× 0.84
A current derating of 16 % and a voltage derating of 10 % are
required. The converter may still be connected to a line supply
voltage of 2 x 1.98 kV 3 AC.
The maximum available output current is 252 A.
Example 2 (water-cooled converter)
Derating data SINAMICS GM150 in IGBT version
For the current, the following applies:
I
≤
I
N
× 0.925 × 0.925 =
I
N
× 0.856
A current derating of 14.4 % is required.
The maximum available output current is 299 A.
Drive unit
6SL3810-2LP33-0AA0
Output voltage
4.16 kV
Input voltage
2 × 2.2 kV
Type rating
2200 kVA, 300 A
Installation altitude
3000 m
Ambient temperature, max.
30 °C
k
H
(air cooling)
0.84
k
T
(ambient temperature)
1.0
k
U
0.9
Drive unit
6SL3815-2LN33-5AA0
Output voltage
3.3 kV
Input voltage
2 × 1.7 kV
Type rating
20.00 kVA, 350 A
Installation altitude
20.00 m
Raw water intake temperature
40 °C
k
H
(water cooling)
0.925
k
T
(raw water intake temperature)
0.925
k
U
1.0
© Siemens AG 2012