SIEMENS
SINAMICS G180
SINAMICS G180 cabinet units
SINAMICS G180 cabinet units
air-cooled and liquid-cooled
3/29
Siemens D 18.1 · 2014
3
■
Technical data
(continued)
Line voltage, supply system type
2 × 400, 415, 460, 500, 575,
690
V 3 AC IT
SINAMICS G180
cabinet units – air-cooled
6SE0180-
2BH33-2
■
A7
6SE0180-
2BH33-6
■
A7
6SE0180-
2BH34-2
■
A7
6SE0180-
2BH35-2
■
A7
6SE0180-
2BH35-7
■
A7
Converter type
(air-cooled)
2T3F-87601-250
2T3F-87601-315
2T3F-87601-400
2T3F-87601-500
2T3F-87601-560
SINAMICS G180
cabinet units – liquid-cooled
6SE0170-
2BH33-2
■
A7
6SE0170-
2BH33-6
■
A7
6SE0170-
2BH34-2
■
A7
6SE0170-
2BH35-2
■
A7
6SE0170-
2BH35-7
■
A7
Converter type
(liquid-cooled)
2T6F-77601-250
2T6F-77601-315
2T6F-77601-400
2T6F-77601-500
2T6F-77601-560
General mechanical data
Max. cable length between converter
and motor with standard insulation
(shielded)
m
100/250
5)
100/250
5)
100/250
5)
100/250
5)
100/250
6)
Line/load connection
L1, L2, L3/U2, V2, W2
For connection cross-sections,
see "Cable cross-sections and
connections" in section
"Configuring instructions"
从新加坡ovals, according to
NRTL
7)
NRTL
7)
NRTL
7)
NRTL
7)
NRTL
7)
1)
Rated power of a typical 2- to 6-pole standard motor.
2)
Typical output voltage dependent on filter and unit type.
3)
Maximum power loss with continuous motor current.
4)
With IP21 protective top cover (110 mm).
5)
Value is applicable with option L10 (strengthened d
v
/d
t
filter; filter is
integrated in additional 400 mm cabinet).
6)
Value is applicable with option L10 (strengthened d
v
/d
t
filter;
filter is integrated in unit).
7)
On request; the voltage range for NRTL units ends at max. 600 V.
© Siemens AG 2014