SIEMENS
SINAMICS G180
SINAMICS G180 compact units and SINAMICS G180 cabinet systems
SINAMICS G180 cabinet systems
2/42
Siemens D 18.1 · 2014
2
■
Options
(continued)
Additional
ordering data
-Z
with order
code and, if
necessary,
with plain text
specification
SINAMICS G180 cabinet systems (compact units installed in a control cabinet)
690 V TN/TT system
690 V IT system
Version – see selection and ordering data
Option text
M
N
O
P
Q
R
S
T
U
V
Cabinet options
Control cabinet base, welded and suitable
for use with transport rollers, in RAL 7035,
h = 200 mm
M05
Control cabinet base, standard version
in RAL 7022/9005, h = 100 mm
M06
Control cabinet base, standard version
in RAL 7022/9005, h = 200 mm
M07
Cable entry from the top: Power cable
M13
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
Door opening angle 180°
M17
Window in door for viewing internal
display
M19
Partitions between compact units for
cabinet systems
M24
Door hinge on left
M28
Cable entry from the top: Control cables
M34
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
Comfort-grip handle with double-bit key lock
M38
Comfort-grip handle with integrated
pushbutton
M39
Comfort-grip handle with cylinder lock
M40
Air supply via cable floor. No filter mats
required in door
M59
Cable entry from the top: Motor cables
M78
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
Special control cabinet paint color:
请注明、
Y09
•和
identification
code
Window in door for viewing internal
components
Y19
•和
identification
code
Control elements and display instruments in control cabinet door
SENTRON PAC3200 power monitoring
device (without current transformer)
G10
SENTRON PAC3200 power monitoring
device (with current transformer)
G11
External 4-line operator panel, supplied
separately packed
K14
External 4-line operator panel integrated
in control cabinet door
K15
Selector switch in form of key-operated
switch
K37
Accessories
Grounding socket outlet 230 V, 50 Hz,
10 A, in control cabinet with 30 mA
ground-fault circuit interrupter,
external incoming supply
L48
Socket outlet 230 V, 50 Hz, 1 A, in control
cabinet with 30 mA ground-fault circuit
interrupter, supplied internally
L49
Magnetically attached cabinet light and
door contact switch
L50
Cabinet heater to protect against
condensation and/or for operation with
supply air temperature of -5 °C or below
L55
Controlled outgoing feeder for motor
heater, 230 V 1 AC, max. 4 kW
N35
Controlled outgoing feeder for external
motor fan, external fan voltage for 3 AC.
Converter line voltage, max. 4 kW
N36
Undervoltage release for main switch or
circuit breaker; specify coil voltage
Y11
•和
identification
code
–
–
–
–
–
–
Controlled outgoing feeder for auxiliary
drive up to max. 4 kW; please specify
type of drive, voltage, number of phases
Y98
•和
identification
code
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
For legends and footnotes, see Page 2/45.
© Siemens AG 2014