SIEMENS
SINAMICS G180
Option descriptions
Standard options
4/29
Siemens D 18.1 · 2014
4
■
Options
(continued)
S01, S02, S03, S04, S06, S08, S09, S11, S12, S21, S22, S23, S24, S31, S32, S41 and G08
Standard accessories packages
Standard accessories packages
Option
Accessories package S01 with main switch, line contactor,
EMERGENCY OFF pushbutton and safety relay, board G03,
local/remote switch
S01
Accessories package S02 with circuit breaker, line contactor,
EMERGENCY OFF pushbutton and safety relay, board G03,
local/remote switch
S02
Accessories package with main switch, line contactor, board G03,
local/remote switch
S03
Accessories package with circuit breaker, line contactor,
board G03, local/remote switch
S04
Accessories package with main switch, line contactor, Calomat,
RCU box connection
S06
Bypass for smooth line synchronization (soft start function)
incl. line-side main switch and contactors at the converter output
and in bypass
S08
Bypass for smooth line synchronization (soft start function) incl.
line-side circuit breaker and contactors at the converter output and
in bypass
S09
Accessories package S11 with line-side main switch, board G03,
local/remote switch
S11
Accessories package S12 with line-side circuit breaker, board G03,
local/remote switch
S12
旁路与线路侧主要开关,接触器在converter output
and in bypass, switchover between manual and automatic,
local/remote switch
S21
Bypass with line-side circuit breaker, contactors at converter
output and in bypass, switchover between manual and automatic,
local/remote switch
S22
旁路与线路侧主要开关,接触器在converter
output and in bypass, EMERGENCY OFF safety relay, switchover
between manual and automatic, local/remote switch
S23
Bypass with line-side circuit breaker, contactors at converter
output and in bypass, EMERGENCY OFF safety relay, switchover
between manual and automatic, local/remote switch
S24
NAMUR accessories package with Test/Normal operation switch,
option G05, terminal strip compliant with NAMUR NE37
(without main switch)
S31
NAMUR accessories package with Test/Normal operation switch,
main switch, line contactor, option G05, terminal strip compliant
with NAMUR NE37
S32
Option description
4-line display in the door
Main switch as switch disconnector incl. lockable door handle
(输入坏蛋rent > 125 A also with short-circuit release)
Circuit breaker with adjustable overcurrent release and short-circuit
release incl. lockable door handle
Main contactor on input for safety-related line disconnection
EMERGENCY OFF safety relay according to EN ISO 13849-1 or SIL 1
1)
according to EN 61508
EMERGENCY OFF pushbutton and EMERGENCY OFF reset in the
cabinet door
Selector switch for local/remote operation in the cabinet door
Output-side converter contactor
Bypass contactor
Hardware for line voltage measurement and synchronizer via the converter
Input-side disconnection possibility for the converter
Motor monitoring also in bypass mode
Manual or automatic bypass switchover
Button "Bypass On" with lamp "Bypass On"
Button "Bypass Off"
Button "Reset motor fault" with lamp "Motor fault"
Terminal strip in accordance with NAMUR recommendation NE37
Selector switch for Test/Normal operation in the cabinet
Peripheral board 2 (G03) incl. ATEX-certified PTC input (G03)
Peripheral board 4 (G05) incl. automatic supply disconnection,
executed in accordance with EN ISO 13849-1 up to Cat. 3 and
ATEX-certified PTC input
1)
SIL 2 available with option
G08
, SIL 3 on request.