SIEMENS
SINAMICS G180
SINAMICS G180 cabinet units
SINAMICS G180 cabinet units
air-cooled and liquid-cooled
3/51
Siemens D 18.1 · 2014
3
■
Options
(continued)
Additional
ordering data
-Z
with order
code and, if
necessary,
with plain text
specification
Air-cooled and liquid-cooled versions of SINAMICS G180 cabinet units
400 V
500 V
690 V
Pulse number
6
12
6
12
6
12
18
24
Version – see selection and ordering data
Option text
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
Output filter
Strengthened
d
v
/d
t
output filter for max.
250/300 m (type-dependent). Design for
longer motor cables available on request
L10
4)
4)
4)
4)
4)
4)
4)
Sine-wave filter integrated in control
cabinet or additional cabinet, suitable for
motor frequencies of
≤
75 Hz, voltage
drop of approximately 10 % of line voltage
L14
H91
6)
H92
6)
H92
6)
H92
6)
5)
H91
6)
H92
6)
5)
–
–
–
–
–
–
–
Sine-wave filter integrated in control
cabinet or additional cabinet, suitable for
motor frequencies of
≤
60 Hz, voltage
drop of approximately 10 % of line voltage
L15
–
–
–
–
–
–
–
–
5)
5)
5)
5)
5)
5)
5)
Standard accessories packages
Peripheral board 4 (G05) instead of
peripheral board 2 (G03) (only in con-
junction with package S01, S02, S03, S04,
S08, S09, S11, S12)
G08
Accessories package S01 with main
switch, line contactor, EMERGENCY OFF
pushbutton and safety relay, board G03,
local/remote switch
S01
Accessories package S02 with circuit
breaker, line contactor, EMERGENCY OFF
pushbutton and safety relay, board G03,
local/remote switch
S02
Accessories package with main switch,
line contactor, board G03, local/remote
switch
S03
Accessories package with circuit breaker,
line contactor, board G03, local/remote
switch
S04
Accessories package with main switch,
line contactor, Calomat, RCU box
connection
S06
旁路的平滑线同步
(soft start function) incl. line-side main
switch and contactors at the converter
output and in bypass
S08
H92
6)
H92
6)
H92
6)
H92
6)
5)
H92
6)
H92
6)
5)
H92
6)
H92
6)
H92
6)
5)
5)
5)
5)
旁路的平滑线同步
(soft start function) incl. line-side circuit
breaker and contactors at the converter
output and in bypass
S09
H92
6)
H92
6)
H92
6)
H92
6)
5)
H92
6)
H92
6)
5)
H92
6)
H92
6)
H92
6)
5)
5)
5)
5)
Accessories package S11 with line-side
main switch, board G03, local/remote
switch
S11
Accessories package S12 with line-side
circuit breaker, board G03, local/remote
switch
S12
Bypass with line-side main switch,
contactors at converter output and in
bypass, switchover between manual and
automatic, local/remote switch
S21
H91
6)
H91
6)
H91
6)
H91
6)
5)
H91
6)
H91
6)
5)
H91
6)
H91
6)
H91
6)
5)
5)
5)
5)
Bypass with line-side circuit breaker,
contactors at converter output and in
bypass, switchover between manual and
automatic, local/remote switch
S22
H91
6)
H91
6)
H91
6)
H91
6)
5)
H91
6)
H91
6)
5)
H91
6)
H91
6)
H91
6)
5)
5)
5)
5)
Bypass with line-side main switch,
contactors at converter output and in
bypass, EMERGENCY OFF safety relay,
switchover between manual and
automatic, local/remote switch
S23
H91
6)
H91
6)
H91
6)
H91
6)
5)
H91
6)
H91
6)
5)
H91
6)
H91
6)
H91
6)
5)
5)
5)
5)
Bypass with line-side circuit breaker,
contactors at converter output and in
bypass, EMERGENCY OFF safety relay,
switchover between manual and
automatic, local/remote switch
S24
H91
6)
H91
6)
H91
6)
H91
6)
5)
H91
6)
H91
6)
5)
H91
6)
H91
6)
H91
6)
5)
5)
5)
5)
For legends and footnotes, see Page 3/56.
© Siemens AG 2014