SIEMENS
5/15
Siemens D 35 · 2017
■
Options
(continued)
5
SINAMICS G120P Cabinet, converter cabinet units
SINAMICS G120P Cabinet, 75 kW to 630 kW
SINAMICS G120P Cabinet
L00
Use in the first environment to EN 61800-3, Category C2
(TN systems or TT systems with grounded neutral point)
To limit the
emitted interference
, the converters are equipped
as standard with a radio interference suppression filter that con-
forms to the limits defined in Category C3. SINAMICS G120P
Cabinet units equipped with the line filter also meet the limits for
use in the first environment (Category C2) as specified in
EN 61800-3.
1)
SINAMICS G120P Cabinet units comply with the
noise immu-
nity
requirements defined in EN 61800-3 as standard for the first
and second environments.
In conjunction with line reactors, line filters also limit the con-
ducted interference emitted by the Power Modules to the limit
values of Category C2 defined in product standard EN 61800-3.
To allow the power cable shield to be connected in conformance
with EMC requirements, an additional EMC shield bus (
M70
op-
tion) is installed in the cabinet. A separate order is not required
in this case.
Note:
Option
L00
increases the cabinet width for frame size JX by
200 mm (7.87 in).
L01
Clean Power version with integrated Line Harmonics Filter
The Clean Power version of SINAMICS G120P Cabinet is
equipped with an innovative Line Harmonics Filter. This filter al-
lows an effective limitation of the line-side harmonic components
arising in converters with a B6 bridge circuit as a result of their
principle of operation. As a result of the significant reduction of
these low-frequency interference variables, voltage distortion
can be effectively counteracted at the line connection point and
thus consistently limited to a value of below 5 % distortion rate
(THD). The limit values stipulated in standard IEEE 519-1992 are
遵守无一例外在网络里dity is suffi-
cient (R
SC
> 20 is required).
By exclusively using passive and thus very robust filter
components, the Line Harmonics Filter in the SINAMICS G120P
Cabinet delivers extremely high availability and maximum
energy efficiency. Furthermore, the filter can remain connected
to the line even when the converter is in stand-by mode by
means of a built-in LC element decoupling circuit. Standard
power disconnection by means of a main contactor (option
L13
)
is still available on request, but is no longer a mandatory
requirement. Thanks to the modular design of the
SINAMICS G120P Cabinet, the Clean Power Filter can be easily
combined with the basic cabinet in an additional cabinet.
The Line Harmonics Filter can be obtained for all available
power ratings in two voltages ranges:
•
380 V to 415 V 3 AC ±10 % (please note voltage limit)
•
500 V至690V 3 AC ±10 %
Notice:
When using option
L01
on 60 Hz line supplies, a limited voltage
tolerance of +8 % applies!
Notice:
If there is no 230 V AC power supply in the customer installation,
it is essential to select option
K74
in order to ensure proper func-
tioning of option
L01
.
The table below specifies the widths and weights of supplemen-
tary cabinets for the Clean Power version of SINAMICS G120P
Cabinet units (option
L01
).
To allow the power cable shield to be connected in conformance
with EMC requirements, an EMC shield bus is installed in the
cabinet at the factory.
Article No.
Rated power
Width of
supplemen-
tary cabinet
Weight of
supplemen-
tary cabinet
Z = +L01
kW
mm (in)
kg (lb)
380 ... 415 V 3 AC
6SL3710-1PE31-5AB0-Z
75
400 (15.75)
400 (882)
6SL3710-1PE31-8AB0-Z
90
400 (15.75)
400 (882)
6SL3710-1PE32-1AB0-Z
110
400 (15.75)
400 (882)
6 sl3710-1pe32-5ab0-z
132
400 (15.75)
400 (882)
6SL3710-1PE33-0AA0-Z
160
400 (15.75)
460 (1014)
6SL3710-1PE33-7AA0-Z
200
400 (15.75)
460 (1014)
6SL3710-1PE34-6AA0-Z
250
400 (15.75)
460 (1014)
6SL3710-1PE35-8AA0-Z
315
600 (23.62)
600 (1323)
6SL3710-1PE36-6AA0-Z
355
600 (23.62)
600 (1323)
6SL3710-1PE37-4AA0-Z
400
600 (23.62)
600 (1323)
6SL3710-1PE38-4AA0-Z
450
800 (31.5)
800 (1764)
6SL3710-1PE38-8AA0-Z
500
800 (31.5)
800 (1764)
6SL3710-1PE41-0AA0-Z
560
800 (31.5)
800 (1764)
500 ... 690 V 3 AC
6SL3710-1PG33-7AA0-Z
315
600 (23.62)
600 (1323)
6SL3710-1PG34-0AA0-Z
355
600 (23.62)
600 (1323)
6SL3710-1PG34-5AA0-Z
400
600 (23.62)
600 (1323)
6SL3710-1PG35-2AA0-Z
450
600 (23.62)
600 (1323)
6SL3710-1PG35-8AA0-Z
500
800 (31.5)
800 (1764)
6SL3710-1PG36-5AA0-Z
560
800 (31.5)
800 (1764)
6SL3710-1PG37-2AA0-Z
630
800 (31.5)
800 (1764)
1)
Applies to shielded motor cable lengths
≤
150 m (492 ft).
© Siemens AG 2017