SIEMENS
SINAMICS DCM
Services and documentation
Range of training courses
7/4
Siemens D 23.1 · 2014
7
■
Overview
SINAMICS DCM Servicing
Description/learning objective
Unplanned stoppages of production machines can cost a lot of
money.
In this course you will learn the proper way to handle the
SINAMICS DC MASTER DC converter. You will be able to adapt
the parameter assignment and carry out data backups for
modifications to the system. In the event of failures you will be in
a better position to analyze the faults and to clear them more
quickly. That will save time and money.
Target group
Service personnel, maintenance personnel
Preconditions
Basic knowledge of electrical engineering
Content
•
Structure and function of the SINAMICS DC MASTER
converter
•
Changing parameters, backing up data and performing
diagnostics with:
- BOP20 and AOP30 operator panels
- STARTER PC program
•
Using the memory card
•
Establishing the signal flow using function charts:
- Setpoint channel
- Inputs and outputs
- Interfaces to fieldbuses
•
Checking the operating state and enable signals
•
Test mode with STARTER:
- Operation with the control panel
- Recording of signals using the trace function
- Triggering for faults and bit patterns
•
Use of the trend recorder function for long-term recording
•
Analysis of alarms and fault messages
•
读出的诊断内存
•
Thyristor diagnostics service function
•
Replacement of Control Unit, fan and fuses
•
Information on servicing DC motors
•
Practical exercises on training equipment with
SINAMICS DC MASTER
Note:
The replacement of components is communicated in
accordance with the operating instructions and the purchasable
spare parts. If required, complete repairs of the converter can be
performed by Siemens Customer Support.
SINAMICS DCM Service and commissioning
Description/learning objective
This training course explains how you adapt the parameter
settings of the converter to the application and the DC motor.
You expand your theoretical knowledge in the form of exercises
carried out on special training equipment. After participating in
the course, you know the functions of a converter and the inter-
faces. You are in a position to safely and quickly commission the
unit. Through routine fault diagnostics and troubleshooting, you
save time and optimize the availability of your plant or system.
Target group
Commissioning engineers, project engineers, service personnel
Preconditions
Basic knowledge of electrical engineering
Content
•
Design and function of the SINAMICS DC MASTER converter:
Control module CUD, power section, field circuit, interfaces
•
Commissioning and parameterizing using the BOP20 and
AOP30 operator panels and the STARTER PC program
•
Using the memory card: Structure and data backup
•
Procedure when commissioning, checking functions
•
Optimizing the closed-loop current and speed control,
automatic optimization
•
Function diagrams: Setpoint channel, inputs and outputs, free
function blocks
•
Information on Drive Control Chart DCC
•
Drive interface to PROFIBUS / PROFINET
•
Expanding the system using Terminal Modules and Sensor
Modules via DRIVE-CLiQ
•
Parallel connection and peer-to-peer coupling
•
Operating states, alarms and fault messages
•
Service functions: Trace, measuring functions, diagnostics
memory
•
Practical exercises using AOP30 and STARTER on training
equipment
Duration
5 days
Order code:
DR-DCM-IH
Duration
5 days
Order code:
DR-DCM-SI
© Siemens AG 2014