SIEMENS
1/91
Siemens D 83.1 · 2016
1
Introduction
General technical specifications
Converter operation – VSD drive configuration
“Converter operation”
(Frequency – control range) – rating plate: Operational torque limits acc. to IEC 60079-0 [29.15]
Setting range 1 : 10
Setting range 1 : 3
Setting range 10 : 17
2)
T
= constant
T
= constant
Any load characteristic
Constant flux
Constant flux
Constant flux
5 ... 50 Hz
16
2
/
3
... 50 Hz
50 ... 87 Hz
5 Hz
Power
50 Hz
Power
5 … 50 Hz
Torque
Current
16
2
/
3
Hz
Power
50 Hz
Power
16
2
/
3
… 50 Hz
Power
Torque
Current
Torque
Current
P
5 Hz
P
50 Hz
T
I
VSD
P
16 2/3 Hz
P
50 Hz
T
I
VSD
P
T
I
VSD
kW
kW
Nm
kW
kW
Nm
A
kW
Nm
identification code
-Z
and order code
C32
“Power data for converter operation, utilization of thermal class F (155 °C)”
0.01
0.19
1.29
0.72
0.07
0.26
1.80
0.79
0.40
1.52
1.33
0.01
0.28
1.89
0.92
0.10
0.38
2.69
1.03
0.60
2.28
1.70
0.03
0.43
2.87
1.24
0.17
0.55
3.93
1.43
0.85
3.28
2.25
0.04
0.55
3.91
1.54
0.24
0.80
5.40
1.82
1.10
4.47
2.90
0.05
0.85
5.70
2.20
0.35
1.10
7.90
2.60
1.70
6.60
4.05
0.07
1.10
7.80
2.85
0.47
1.60
10.7
3.45
2.30
9.00
5.40
0.13
1.70
11.5
3.85
0.7
2.30
15.6
4.80
3.40
13.00
7.50
0.18
2.40
15.7
5.10
1.00
3.20
21.3
6.40
4.70
17.70
9.90
0.23
2.80
18.8
6.80
1.20
3.80
25.3
8.00
6.30
23.50
13.30
0.35
4.20
27.3
9.20
1.70
5.60
36.7
11.4
8.60
32.20
18.10
0.46
5.40
35.3
11.4
2.30
7.20
47.3
14.3
11.80
43.90
23.50
0.70
8.40
54.8
17.0
3.60
11.2
73.2
21.0
17.30
64.20
33.00
1.00
11.5
74.8
23.0
4.90
15.3
99.7
28.5
23.60
87.20
44.50
1.10
12.9
83.6
26.0
5.40
17.2
111.9
33.0
29.20
108.30
55.00
1.20
14.7
95.6
30.5
6.20
19.6
127.8
37.5
34.70
128.80
66.00
1.80
21.0
135.7
42.0
8.90
27.9
181.1
53.0
47.30
175.00
88.00
2.30
26.8
173.4
49.0
10.8
33.6
218
60.0
- - - - - -
- - - - - -
- - - - - -
2.90
32.7
211
61.0
13.2
40.9
265
74.0
- - - - - -
- - - - - -
- - - - - -
3.60
40.0
258
76.0
16.3
50.1
323
92.0
- - - - - -
- - - - - -
- - - - - -
5.50
59.4
382
107
24.3
74.2
478
131
- - - - - -
- - - - - -
- - - - - -
6.10
65.8
422
122
26.9
82.0
527
146
- - - - - -
- - - - - -
- - - - - -
8.70
92.0
592
168
37.9
115
739
205
- - - - - -
- - - - - -
- - - - - -
9.90
105
672
188
43.1
130.5
839
230
- - - - - -
- - - - - -
- - - - - -
11.2
117
750
215
48.2
146
936
255
- - - - - -
- - - - - -
- - - - - -
14.0
146.5
937
265
60.2
182.5
1169
320
- - - - - -
- - - - - -
- - - - - -
15.6
164.5
1055
305
67.6
205
1318
365
- - - - - -
- - - - - -
- - - - - -
19.5
205
1330
395
84.0
255
1658
470
- - - - - -
- - - - - -
- - - - - -
19.5
205
1330
395
84.0
255
1658
470
- - - - - -
- - - - - -
- - - - - -
19.7
207
1330
395
85.0
258
1660
470
- - - - - -
- - - - - -
- - - - - -
22.6
237
1520
450
97.5
295
1897
540
- - - - - -
- - - - - -
- - - - - -
28.8
303
1942
560
124.5
378
2424
680
- - - - - -
- - - - - -
- - - - - -
2)
Optional voltage with
9
at the 11th position of the Article No. and order
code
L1P
: 230/400 V
/Y, 50 Hz; 400 V
87Hz (operating values at 87 Hz
and motor in
circuit).
© Siemens AG 2016