SIEMENS
13/97
Siemens IC 10 · 2017
SIRIUS ACT Pushbuttons and Indicator Lights
Enclosures
Pushbuttons and indicator lights in the enclosure for AS-Interface
13
■
Overview
With AS-Interface enclosures, distributed SIRIUS ACT
pushbuttons and indicator lights can be quickly connected to
the AS-Interface communication system. Using suitable
components you can make your own enclosures with integrated
AS-Interface or flexibly modify existing enclosures.
Enclosures for AS-Interface
Enclosures
Color of enclosure top:
•
Gray, RAL 7035
•
Yellow, RAL 1004 for EMERGENCY-STOP
Color of enclosure base:
•
Black, RAL 9005
Equipping with AS-Interface slaves
The following slaves are available for connecting the command
points:
•
Slave in A/B technology with 4 digital inputs and 3 digital
outputs (4 DI/3 DQ)
•
Slave with 4 digital inputs and 4 digital outputs (4 DI/4 DQ)
•
F slave with 2 safe inputs for EMERGENCY STOP mushroom
pushbutton (2 F-DI), also with integrated red LED for the
照亮紧急停止蘑菇按钮。
The following table shows the maximum number of slaves
possible:
Connection
One set of links is required in each case to connect a slave to
contact modules, LED modules, and the connection element.
The connection elements are mounted in the front-end cable
glands and are used to connect the AS-Interface or bring
unused inputs or outputs out of the enclosure.
For connection to AS-Interface, the following options are
available:
•
Terminal for shaped AS-Interface cable. The cable is
contacted by the insulation piercing method and routed past
the enclosure on the outside (possible only with plastic
enclosure).
•
Cable gland for the shaped AS-Interface cable or round
cable. The cable is routed into the enclosure (preferable for
metal enclosure).
•
使用M12插头连接。
If less than all inputs/outputs of the installed slaves in an
enclosure are used for connecting the command devices, free
inputs and outputs can be routed on request to the outside
through an M12 socket on the top or bottom side of the
enclosure.
To supply inputs with power, the S+ connection of the slave must
be assigned to the socket, for outputs the OUT– connection
must be assigned. Addressing is performed using the
AS-Interface connections or the integrated addressing socket.
An external power supply is not required.
Enclosures with standard fittings
Enclosures with standard fittings are available with:
•
1 to 3 command points
•
Operational voltage through AS-Interface (approx. 30 V)
•
Vertical mounting type
•
Plastic enclosure with plastic actuators and indicators, metal
enclosure with metal actuators and indicators
The enclosures without EMERGENCY STOP each have one
module with 4I/3O; the enclosures with EMERGENCY STOP
mushroom pushbuttons have a safe AS-Interface slave inte-
grated in the enclosure. Enclosures with EMERGENCY STOP
mushroom pushbuttons are fitted with two NC contact modules,
which are wired to the safe F slave.
The contact modules and LED modules (with spring-type
terminals) of the command devices and the AS-Interface slaves
are mounted in the base of the enclosure and connected using
cables. The plastic enclosures are designed with a connection
作为接口的扁平电缆(电缆运行along the outside
of the enclosure). With metal enclosures, the AS-Interface cable
is run inside the enclosure.
The enclosures with EMERGENCY STOP mushroom
pushbuttons are also available with an M12 connector.
Customized enclosures (selection by configurator)
To order customized 3SU18 AS-Interface enclosures with
pushbuttons and indicator lights, the configurator must be used
to select the fittings. An electronic order form will be generated
for the options.
For the configurator,
see
www.siemens.com/sirius-act/configurator
.
Number of
command points
Number of slaves
for enclosures
without EMERGENCY STOP
Number of slaves
for enclosures
with EMERGENCY STOP
1
--
1 x F slave 2 F-DI
2
1 x slave 4 DI/4 DQ or
4 DI/3 DQ
--
3
1 x slave 4 DI/4 DQ or
4 DI/3 DQ
1 x slave 4 DI/4 DQ or
4 DI/3 DQ + 1 x F slave
4
2 x slave 4 DI/4 DQ or
4 DI/3 DQ
2 x slave 4 DI/4 DQ or
4 DI/3 DQ + 1 x F slave
6
2 x slave 4 DI/4 DQ or
4 DI/3 DQ
2 x slave 4 DI/4 DQ or
4 DI/3 DQ + 1 x F slave
© Siemens AG 2016