年代IEMENS
8/38
年代iemens IC 10 · 2017
* You can order this quantity or a multiple thereof.
插图是近似的。
Load Feeders and Motor Starters for Use in the Control Cabinet
年代IRIUS 3RA2 Load Feeders
3RA22 reversing starters for snapping onto standard mounting rails or for screw fixing
8
Footnotes for pages 8/37 and 8/38:
1)
For push-in lugs,
see "Accessories" on page 8/52
.
2)
For auxiliary switches,
see "Accessories" on page 8/45
.
3)
The actual starting and rated data of the motor to be protected must be
considered when selecting the units.
4)
RH = assembly kit for reversing duty and standard rail mounting in sizes
年代0 and S2.
5)
年代uitable for use with IE3/IE4 motors up to a starting current of 256 A.
For higher starting currents we recommend using size S2.
6)
Maximum permissible current setting at motor starter protector 65 A.
Type of coordination "1" at
I
q
= 150 kA at 400 V
(the motor starter protector is compatible with type of coordination "2")
年代00
For load feeders for lower outputs, see this table at
type of coordination "2".
年代00
1.5
3.6
3.5 ... 5
11-1FA10
15-1BB42
1921-1DA00
+ 2913-2AA1
2
3RA2210-1FA15-2BB4
1
1 unit
41D
2.2
4.9
4.5 ... 6.3
11-1GA10
2
3RA2210-1GA15-2BB4
1
1 unit
41D
3
6.5
5.5 ... 8
11-1HA10
2
3RA2210-1HA15-2BB4
1
1 unit
41D
4
8.5
7 ... 9
11-1JA10
16-1BB42
2
3RA2210-1JA16-2BB4
1
1 unit
41D
5.5
11.5
9 ... 12
11-1KA10
17-1BB42
2
3RA2210-1KA17-2BB4
1
1 unit
41D
7.5
15.5
10 ... 16
11-4AA10
18-1BB42
2
3RA2210-4AA18-2BB4
1
1 unit
41D
3RA2210
3RA2220
Reversing duty
Rated control supply voltage 24 V DC
With screw terminals
•
年代crew fixing with two push-in lugs per load feeder
possible
1)
•
Without standard mounting rail adapter for size S00
•
With two standard mounting rail adapters for size S0
for mechanical reinforcement (included in the scope of
delivery)
•
The motor starter protector and contactor are mechani-
cally and electrically connected by means of the link
module.
•
Auxiliary switches
2)
on the motor starter protector and
the contactor can be easily fitted thanks to the modular
system.
•
With contactor sizes S0, S2 and S3, an integrated
NO contact is still available for free use.
年代ize
年代tandard
three-phase
motor
4-pole at
400 V AC
3)
Adjustable
当前的
response
value of the
inverse-time
delayed over-
load release
Comprising the following
single devices
年代D
Fuseless
load feeder
PU
(UNIT,
年代ET, M)
PS*
PG
Motor
starter
protector
+ 2 contac-
tors
+ Link module
+ RH assem-
bly kit
4)
/
wiring kit
年代tan-
dard
output
P
Motor
当前的
I
(guide
value)
年代crew terminals
Article No.
Basic
price
per PU
kW
A
A
d
1
ToC
© Siemens AG 2016