SCALANCE XR-300 managed
Permitted ambient conditions
Ambient temperature
• during operating
-40 … +70 °C
-40 … +70 °C
-40 … +70 °C
• during storage
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
• during transport
-40 … +85 °C
-40 … +85 °C
-40 … +85 °C
• Comment
Reduced operating temperature
through the use of media modules
(-40 °C to +70 °C) or
SFP plug-in transceivers
(-40 °C to +60 °C).
If the device is installed in the vertical
position, the maximum operating
temperature is reduced to +50 °C.
Reduced operating temperature
through the use of media modules
(-40 °C to +70 °C) or
SFP plug-in transceivers
(-40 °C to +60 °C).
If the device is installed in the vertical
position, the maximum operating
temperature is reduced to +50 °C.
Reduced operating temperature
through the use of media modules
(-40 °C to +70 °C) or
SFP plug-in transceivers
(-40 °C to +60 °C).
If the device is installed in the vertical
position, the maximum operating
temperature is reduced to +50 °C.
Relative humidity at 25 °C without
condensation during operating
maximum
95 %
95 %
95 %
Ambient condition for (standard)
operation mode
Conformal coating, no
Conformal coating, no
Conformal coating, yes
布鲁泰克tion class IP
IP20
IP20
IP20
Design, dimensions and weight
Design
19" rack
19" rack
19" rack
Width
483 mm
483 mm
483 mm
Height
44 mm
44 mm
44 mm
Depth
305 mm
305 mm
305 mm
Net weight
5.5 kg
5.5 kg
5.5 kg
Mounting type
• 19-inch installation
Yes
Yes
Yes
• 35 mm DIN rail mounting
No
No
No
• wall mounting
No
No
No
• S7-300 rail mounting
No
No
No
Mounting type
When used in shipbuilding,
the device must be secured
in the 19" rack at four points
When used in shipbuilding,
the device must be secured
in the 19" rack at four points
When used in shipbuilding,
the device must be secured
in the 19" rack at four points
Product properties, functions,
components
general
Cascading in the case of a
redundant ring at reconfiguration time
of < 0.3 s
50
50
50
Cascading in cases
恒星的结构
Any (depending only on signal
propagation time)
Any (depending only on signal
propagation time)
Any (depending only on signal
propagation time)
Product functions
management,
configuration
Product function
• CLI
Yes
Yes
Yes
• web-based management
Yes
Yes
Yes
• MIB support
Yes
Yes
Yes
• TRAPs via email
Yes
Yes
Yes
• Configuration with STEP 7
Yes
Yes
Yes
• RMON
Yes
Yes
Yes
• SMTP server
-
-
-
• Port mirroring
Yes
Yes
Yes
• CoS
Yes
Yes
Yes
• PROFINET IO diagnosis
Yes
Yes
Yes
• switch-managed
Yes
Yes
Yes
Article No.
6GK5324-0GG00-1AR2
6GK5324-0GG00-1HR2
6GK5324-0GG00-1CR2
Product-type designation
SCALANCE XR324-12M
SCALANCE XR324-12M
SCALANCE XR324-12M TS
© Siemens AG 2014